| All functions of the air conditioning system do not operate
|
IG power source circuit
|
|
| Back-up power source circuit
|
|
| LIN communication circuit
|
|
| Air conditioning amplifier assembly
|
|
| Air flow control: No blower operation
|
Blower motor circuit
|
|
| LIN communication circuit
|
|
| Air conditioning amplifier assembly
|
|
| Air flow control: No blower control
|
Blower motor circuit
|
|
| LIN communication circuit
|
|
| Air conditioning amplifier assembly
|
|
| Air flow control: Insufficient air flow
|
Blower motor circuit
|
|
| Air conditioning amplifier assembly
|
|
| Temperature control: cooling effectiveness is poor
|
Refrigerant gas volume check using the Techstream
|
|
| Refrigerant volume
|
|
| Refrigerant pressure
|
|
| Cooler expansion valve
|
|
| Cooler compressor assembly (w/ Magnet Clutch)
|
|
| Compressor assembly with pulley (w/o Magnet Clutch)
|
|
| Air conditioning amplifier assembly
|
|
| Temperature control: No cool air comes out
|
Refrigerant gas volume check using the Techstream
|
|
| Refrigerant volume
|
|
| Refrigerant pressure
|
|
| Air conditioning pressure sensor circuit
|
|
| Air conditioning compressor magnetic circuit (w/ Magnet Clutch)
|
|
| Compressor lock sensor circuit (w/ Magnet Clutch)
|
|
| Compressor solenoid circuit
|
|
| Air mix damper control servo motor circuit (for driver side)
|
|
| Air mix damper control servo motor circuit (for front passenger side)
|
|
| Evaporator temperature sensor circuit
|
|
| Room temperature sensor circuit
|
|
| Ambient temperature sensor circuit
|
|
| LIN communication circuit
|
|
| Cooler expansion valve
|
|
| No. 2 air conditioning radiator damper servo sub-assembly (driver side air mix)
|
|
| No. 3 air conditioning radiator damper servo sub-assembly (front passenger side air mix)
|
|
| Air conditioning harness assembly
|
|
| Air conditioning amplifier assembly
|
|
| ECM
|
|
| Temperature control: No warm air comes out
|
Air mix damper control servo motor circuit (for driver side)
|
|
| Air mix damper control servo motor circuit (for front passenger side)
|
|
| Evaporator temperature sensor circuit
|
|
| Room temperature sensor circuit
|
|
| Ambient temperature sensor circuit
|
|
| LIN communication circuit
|
|
| No. 2 air conditioning radiator damper servo sub-assembly (driver side air mix)
|
|
| No. 3 air conditioning radiator damper servo sub-assembly (front passenger side air mix)
|
|
| Air conditioning harness assembly
|
|
| Air conditioning amplifier assembly
|
|
| ECM
|
|
| Temperature control: Output air is warmer or cooler than the set temperature or response is slow
|
Refrigerant gas volume check using the Techstream
|
|
| Refrigerant volume
|
|
| Refrigerant pressure
|
|
| Air conditioning compressor magnetic clutch circuit (w/ Magnet Clutch)
|
|
| Compressor lock sensor circuit (w/ Magnet Clutch)
|
|
| Compressor solenoid circuit
|
|
| Solar sensor circuit (for driver side)
|
|
| Solar sensor circuit (for front passenger side)
|
|
| Room temperature sensor circuit
|
|
| Ambient temperature sensor circuit
|
|
| Air mix damper control servo motor circuit (for driver side)
|
|
| Air mix damper control servo motor circuit (for front passenger side)
|
|
| Air inlet damper control servo motor circuit
|
|
| LIN communication circuit
|
|
| Radiator unit sub-assembly
|
|
| Cooler expansion valve
|
|
| No. 2 air conditioning radiator damper servo sub-assembly (driver side air mix)
|
|
| No. 3 air conditioning radiator damper servo sub-assembly (front passenger side air mix)
|
|
| No. 1 blower damper servo sub-assembly (air inlet)
|
|
| Air conditioning harness assembly
|
|
| Air conditioning amplifier assembly
|
|
| ECM
|
|
| Temperature control: No temperature control (only Max. cool or Max. hot)
|
Air mix damper control servo motor circuit (for driver side)
|
|
| Air mix damper control servo motor circuit (for front Passenger side)
|
|
| Room temperature sensor circuit
|
|
| Ambient temperature sensor circuit
|
|
| Evaporator temperature sensor circuit
|
|
| Solar sensor circuit (for driver side)
|
|
| Solar sensor circuit (for front passenger side)
|
|
| LIN communication circuit
|
|
| No. 2 air conditioning radiator damper servo sub-assembly (driver side air mix)
|
|
| No. 3 air conditioning radiator damper servo sub-assembly (front passenger side air mix)
|
|
| Air conditioning harness assembly
|
|
| Air conditioning amplifier assembly
|
|
| No air inlet control
|
Air inlet damper control servo motor circuit
|
|
| LIN communication circuit
|
|
| No. 1 blower damper servo sub-assembly (air inlet)
|
|
| Air conditioning harness assembly
|
|
| Air conditioning amplifier assembly
|
|
| No air flow mode control
|
Air outlet damper control servo motor circuit
|
|
| LIN communication circuit
|
|
| No. 1 air conditioning radiator damper servo sub-assembly (mode)
|
|
| Air conditioning harness assembly
|
|
| Air conditioning amplifier assembly
|
|
| Diagnostic trouble codes (DTCs) are not recorded. Set mode is cleared when ignition switch is off.
|
Back-up power source circuit
|
|
| Air conditioning amplifier assembly
|
|