MALFUNCTION DESCRIPTION
The EV control ECU monitors the high-voltage wiring between the EV supply battery assembly and inverter with converter assembly and detects a short circuit malfunction or high-voltage system operation malfunction.
The cause of this malfunction may be one of the following:
Battery current sensor (IB) malfunction
Motor generator control ECU (MG ECU) malfunction
Communication (wire harness) malfunction
EV supply battery assembly malfunction
No. 1 EV battery junction block assembly malfunction
Inverter with converter assembly malfunction
Air conditioner system malfunction
High-voltage wire harness malfunction
High-voltage connector or connection malfunction
FC converter assembly malfunction
FC system high-voltage auxiliary machine malfunction
EV control ECU malfunction
Low voltage wire harness malfunction
Low voltage connector malfunction
FC system high-voltage auxiliary machine malfunction
Refer to the description for DTC P0AE411.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AE411
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1C8149 | High Voltage Power Resource Circuit Consumption Circuit Short | High-voltage circuit malfunctions between the EV supply battery and inverter with converter assembly.
Excessive overcurrent equal to a short occurs during precharge (time from when SMRP turns on until SMRG turns on). (1 trip detection logic) |
·
Compressor with motor assembly ·
Inverter with converter assembly ·
No. 1 EV battery junction block assembly ·
Floor under wire ·
EV control ECU ·
FC converter assembly ·
FC inverter input terminal ·
Air conditioning compressor cable ·
Electric heater sub-assembly ·
FC cooling water pump cable ·
No. 1 battery pack wire ·
FC junction cable ·
FC cooling water pump inverter assembly ·
FC hydrogen pump inverter assembly ·
Front compartment main wire |
Master Warning:
Comes on |
EV | A |
| P1C8249 | High Voltage Power Resource Circuit Over Loading | High-voltage circuit malfunctions between the EV supply battery and inverter with converter assembly.
Small battery overcurrent occurs during precharge (time from when SMRP turns on until SMRG turns on) and current continues to flow after precharge. (1 trip detection logic) |
·
Compressor with motor assembly ·
Inverter with converter assembly ·
No. 1 EV battery junction block assembly ·
Floor under wire ·
EV control ECU ·
FC converter assembly ·
FC inverter input terminal ·
Air conditioning compressor cable ·
Electric heater sub-assembly ·
FC cooling water pump cable ·
No. 1 battery pack wire ·
FC junction cable ·
FC cooling water pump inverter assembly ·
FC hydrogen pump inverter assembly ·
Front compartment main wire |
Master Warning:
Comes on |
EV | A |
| DTC No. | Data List |
|---|---|
| P1C8149 | ·
Hybrid/EV Battery Voltage ·
Hybrid/EV Battery Current ·
VL-Voltage before Boosting ·
VH-Voltage after Boosting |
| P1C8249 |
After repairs have been completed, clear the DTCs and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 10 minutes or more.
Turn the ignition switch to ON (READY) and wait for 30 seconds or more.
Turn the ignition switch off and wait for 10 minutes or more.
Enter the following menus: Powertrain / EV / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Refer to the wiring diagram for DTC P0AA649.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AA649
Refer to the wiring diagram for DTC P1CCC96.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P1CCC96
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV battery service plug grip and FC converter power outlet cable on FC converter side.
Make sure to remove the service plug gripfirst.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the EV supply battery assembly
Disconnecting the low voltage connector of the FC converter assembly
To prevent electric shock, make sure to remove the EV battery service plug grip and FC converter power outlet cable on FC converter side to cut off the high voltage circuit before servicing the vehicle.
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, store them according to the following guidelines to prevent other technicians from accidentally reconnecting them while work is being performed on the high voltage systems.
The technician performing the work should put the EV battery service plug grip in their pocket and carry it with them.
Remove the FC converter power outlet cable on FC converter side with a "HIGH-VOLTAGE, DO NOT TOUCH" caution tag attached to it for other technicians.
| *a | Without waiting for 10 minutes |
After removing the service plug grip and FC converter power outlet cable on FC converter side, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly snd FC converter assembly.
Make sure to insulate the high-voltage connectors and terminals of the EV supply battery assembly with insulating tape after removing it.
If the EV supply battery assembly stored without insulating the connectors and terminals, electric shock or fire may result.
Since high voltage accumulates within the FC stack assembly with FC converter, never perform the work of separating the FC stack assembly with FC converter into the FC converter assembly and FC stack assembly without first performing electrical charge discharge (forced electrical charge discharge or electrical charge self-discharge), because doing so is dangerous.
Click hereEngine / Hybrid System>FC CONTROL>FC STACK>REMOVAL
Removing and installing the FC stack assembly without first discharging the electrical charge may result in an electric shock due to the high voltage circuit.
After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| P1C8149 or P1C8249 only is output, or DTCs except the ones in the tables below are also output | A |
| Any hybrid control system DTCs in the table below are output | B |
| Any hybrid battery system DTCs in the table below are output | C |
| Any FC control system DTCs in the table below are output | D |
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Microcomputer malfunction | Hybrid control system | P060647 | Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure |
| P060B49 | Hybrid/EV Powertrain Control Module A/D Processing Internal Electronic Failure | ||
| P060687 | Hybrid/EV Powertrain Control Module Processor to Monitoring Processor Missing Message | ||
| P060A47 | Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog / Safety MCU Failure | ||
| P060A87 | Hybrid/EV Powertrain Control Module Processor from Monitoring Processor Missing Message | ||
| Hybrid battery system | P060B49 | Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure | |
| P060687 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message | ||
| P060A47 | Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure | ||
| P060A87 | Hybrid/EV Battery Energy Control Module Processor from Monitoring Processor Missing Message | ||
| P060B16 | Hybrid/EV Battery Energy Control Module A/D Processing Circuit Voltage Below Threshold | ||
| P0E2D00 | Hybrid/EV Battery Energy Control Module Hybrid/EV Battery Monitor Performance | ||
| Communication system malfunction | Hybrid control system | U011187 | Lost Communication with Hybrid/EV Battery Energy Control Module "A" Missing Message |
| Sensor and actuator circuit malfunction | Hybrid control system | P0B231C | Hybrid/EV Battery "A" Voltage Sensor Voltage Out of Range |
| P0ABF00 | Hybrid/EV Battery Current Sensor "A" Circuit Range/Performance | ||
| P0A1114 | DC/DC Converter Enable Circuit Short to Ground or Open | ||
| P0A1112 | DC/DC Converter Enable Circuit Short to Auxiliary Battery | ||
| P1CCC96 | DC/DC Converter Enable Component Internal Failure | ||
| Hybrid battery system | P0ABF11 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground | |
| P0B0E11 | Hybrid/EV Battery Current Sensor "B" Circuit Short to Ground | ||
| P0B0E15 | Hybrid/EV Battery Current Sensor "B" Circuit Short to Auxiliary Battery or Open | ||
| P0ABF15 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open | ||
| P301A1C | Hybrid Battery Stack 1 Cell Voltage Detection Voltage Out of Range | ||
| P1A001C | Hybrid Battery Stack 2 Cell Voltage Detection Voltage Out of Range | ||
| P1AFD1C | Flying Capacitor/Internal Control Module Hybrid/EV Battery Monitor Voltage Out of Range | ||
| P0ABF28 | Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0ABF2A | Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range | ||
| P1CBB12 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery | ||
| P1CBB14 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open | ||
| P0B1362 | Hybrid/EV Battery Current Sensor "A"/"B" Signal Compare Failure | ||
| System malfunction | Hybrid control system | P0A1F94 | Hybrid/EV Battery Energy Control Module Unexpected Operation |
| Motor generator control system | P0D3319 | DC/DC Converter Circuit Current Above Threshold | |
P1C8149 or P1C8249 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Post-procedure1
Turn the ignition switch off.
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
D
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P056014
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A001C
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A20 inverter with converter assembly connector.
Disconnect the A17 EV control ECU connector.
Procedure1
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
| *b | Rear view of wire harness connector
(to EV Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A20,A17)Location & Routingewd_type=routing;type=c,c;code=A20,A17 Click Connector(A17)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A17;pinno=18 |
||
| A20-5 (NODD) - A17-18 (NODD) | Ignition switch off | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A20,A17)Location & Routingewd_type=routing;type=c,c;code=A20,A17 Click Connector(A17)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A17;pinno=18 |
||
| A20-5 (NODD) or A17-18 (NODD) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the A17 EV control ECU connector.
Reconnect the A20 inverter with converter assembly connector.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
Procedure1
| *a | Component with harness connected
(EV Control ECU) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A17)Location & Routingewd_type=routing;type=c;code=A17 Click Connector(A17)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A17;pinno=18,4 |
||
| A17-18 (NODD) - A17-4 (E1) | Ignition switch ON | Below 1.5 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD |
| *B | for RHD |
Disconnect the FC cooling water pump cable from the FC converter assembly.
Procedure1
| *1 | Shield Ground |
| *a | FC Cooling Water Pump Cable
(FC Converter Assembly Side) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection
(Tester Probe Polarity) |
Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(b4)Location & Routingewd_type=routing;type=c;code=b4 Click Connector(b4)Engine Compartment>FC Cooling Water Pump Cable>FC Converter Assemblyewd_type=component;type=c;code=b4;pinno=1,2 |
||
| b4-1 (N) (Negative (-) probe) - b4-2 (P) (Positive (+) probe) | Ignition switch off | 100 kΩ or higher |
Do not use a megohmmeter.
Read the resistance after the value has stabilized.
Be sure to inspect with connecting the tester probes to the tips of the terminal.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the FC cooling water pump cable.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD |
| *B | for RHD |
Disconnect the FC junction cable connectors, floor under wire and FC cooling water pump cable from the FC converter assembly.
Procedure1
| *a | Component without harness connected
(FC Converter Assembly) |
Measure the resistance according to the value(s) inthe table below.
Do not use a megohmmeter.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(N3)Location & Routingewd_type=routing;type=c;code=N3 Click Connector(N3)Engine Compartment>Floor Under Wire>FC Converter Assemblyewd_type=component;type=c;code=N3;pinno=1,2 |
||
| N3-1 (CEI) (Negative (-) probe) - N3-2 (CBI) (Positive (+) probe) | Ignition switch off | 10 kΩ or higher |
If the polarity of the tester probes is wrong, the correct value cannot be measured.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD |
| *B | for RHD |
Disconnect the front compartment main wire connector from the inverter with converter assembly.
Make sure that no foreign matter has entered or contaminated the front compartment main wire connector.
Procedure1
| *1 | Shield Ground |
| *a | Front Compartment Main Wire
(Inverter with Converter Assembly Side) |
Measure the resistance according to the value(s) inthe table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A32)Location & Routingewd_type=routing;type=c;code=A32 |
||
| A32-1 (ACPE) (Negative (-) probe) - A32-2 (ACPB) (Positive (+) probe) | Ignition switch off | 100 MΩ or higher |
Do not use a megohmmeter.
Read the resistance after the value hasstabilized.
Be sure to inspect with connecting thetester probes to the tips of the terminal.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the front compartment main wire connector.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD |
| *B | for RHD |
Disconnect the FC junction cable from the inverter with converter assembly.
Procedure1
| *1 | Shield Ground |
| *a | Front view of FC Junction Cable connector
(Inverter with Converter Assembly Side) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(x1)Location & Routingewd_type=routing;type=c;code=x1 Click Connector(x1)Engine Compartment>FC Junction Cable>Inverter with Converter Assemblyewd_type=component;type=c;code=x1;pinno=1,2 |
||
| x1-1 (P) - x1-2 (N) | Ignition switch off | 10 kΩ or higher |
Be sure not to damage or deform the terminal being inspected.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the FC junction cable.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD |
| *B | for RHD |
Remove the connector cover assembly from the inverter with converter assembly.
| *A | for LHD |
| *B | for RHD |
Disconnect the front compartment main wire from the inverter with converter assembly.
Make sure that no foreign matter has entered or contaminated the front compartment main wire.
| *A | for LHD |
| *B | for RHD |
Disconnect the FC junction cable from the inverter with converter assembly.
Make sure that no foreign matter has entered or contaminated the FC junction cable.
Procedure1
| *A | for LHD |
| *B | for RHD |
Measure the resistance according to the value(s) in the table below.
Do not use a megohmmeter.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (-) (Negative (-) probe) - 1 (+) (Positive (+) probe) | Ignition switch off | 10 kΩ or higher |
Be sure to inspect with connecting thetester probes to the tips of the terminal.
Perform an inspection with the FC junction cable and front compartment main wire removed from the inverter with converter assembly.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG
Click hereEngine / Hybrid System>FC CONTROL>CONVERTER ASSEMBLY>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>FC CONTROL>CONVERTER ASSEMBLY>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
Remove the FC inverter input junction cover from the FC converter assembly.
Click hereEngine / Hybrid System>FC CONTROL>CONVERTER ASSEMBLY>DISASSEMBLY
Procedure1
Measure the resistance according to the value(s) inthe table below.
| *a | FC Inverter Junction Cover | - | - |
Do not use a megohmmeter.
Perform an inspection with the FC inverter input terminal and air conditioning compressor cable still installed to FC converter input junction cover.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(N3)Location & Routingewd_type=routing;type=c;code=N3 Click Connector(N3)Engine Compartment>Floor Under Wire>FC Converter Assemblyewd_type=component;type=c;code=N3;pinno=1,2 |
||
| N3-1 (CEI) (Negative (-) probe) - N3-2 (CBI) (Positive (+) probe) | Ignition switch off | 10 MΩ or higher |
If the polarity of the tester probes is wrong, thecorrect value cannot be measured.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the front compartment main wire connector.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD |
| *B | for RHD |
Disconnect the FC cooling water pump cable from the FC converter assembly.
Disconnect the FC cooling water pump cable from the compressor with motor assembly.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>COMPRESSOR>REMOVAL
Procedure1
| *1 | Shield Ground |
| *a | FC Cooling Water Pump Cable
(Inverter with Converter Assembly Side) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(b4)Location & Routingewd_type=routing;type=c;code=b4 Click Connector(b4)Engine Compartment>FC Cooling Water Pump Cable>FC Converter Assemblyewd_type=component;type=c;code=b4;pinno=1,2 |
||
| b4-1 (N) - b4-2 (P) | Ignition switch off | 10 kΩ or higher |
Be sure to inspect with connecting the tester probes to the tips of the terminal.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the FC cooling water pump cable.
OK
NG
Pre-procedure1
Remove the air conditioning compressor cable from the FC inverter input junction cover.
Remove the air conditioning compressor cable from the FC inverter input terminal.
Procedure1
| *a | Air Conditioning Compressor Cable |
Measure the resistance according to the value(s) inthe table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(b4)Location & Routingewd_type=routing;type=c;code=b4 Click Connector(b4)Engine Compartment>FC Cooling Water Pump Cable>FC Converter Assemblyewd_type=component;type=c;code=b4;pinno=1,2 |
||
| b4-1 (N) - b4-2 (P) | Ignition switch off | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Click hereEngine / Hybrid System>FC CONTROL>CONVERTER ASSEMBLY>DISASSEMBLY
| Proceed to |
|---|
| NEXT |
NEXT
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the N1 and N2 floor under wire from the No. 1 EV battery junction block assembly.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *1 | Component without harness connected
(No. 1 EV Battery Junction Block Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(N1,N2)Location & Routingewd_type=routing;type=c,c;code=N1,N2 Click Connector(N1)Body>Floor Under Wire>No. 1 EV Battery Junction Block Assemblyewd_type=component;type=c;code=N1;pinno=1 Click Connector(N2)Body>Floor Under Wire>No. 1 EV Battery Junction Block Assemblyewd_type=component;type=c;code=N2;pinno=1 |
||
| N1-1 (CBI) - N2-1 (CEI) | Ignition switch off | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the N1 and N2 floor under wire.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Procedure1
| *A | for LHD |
| *B | for RHD |
Disconnect the floor under wire from the FC converter assembly.
Make sure that no foreign matter has entered or contaminated the floor under wire.
Disconnect the N1 and N2 floor under wire from the NO. 1 EV battery junction block assembly.
| *1 | Shield Ground |
| *a | Floor Under Wire
(FC Converter Assembly Side) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(N3)Location & Routingewd_type=routing;type=c;code=N3 Click Connector(N3)Engine Compartment>Floor Under Wire>FC Converter Assemblyewd_type=component;type=c;code=N3;pinno=1,2 |
||
| N3-1 (CEI) - N3-2 (CBI) | Ignition switch off | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the N1 and N2 floor under wire.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD |
| *B | for RHD |
Disconnect the FC junction cable from the inverter with converter assembly.
Procedure1
| *A | for LHD |
| *B | for RHD |
Disconnect the FC junction cable from the FC converter assembly.
Make sure that no foreign matter has entered or contaminated the FC junction cable.
| *1 | Shield Ground |
| *a | Front view of FC Junction Cable connector
(Inverter with Converter Assembly Side) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(x1)Location & Routingewd_type=routing;type=c;code=x1 Click Connector(x1)Engine Compartment>FC Junction Cable>Inverter with Converter Assemblyewd_type=component;type=c;code=x1;pinno=1,2 |
||
| x1-1 (P) - x1-2 (N) | Ignition switch off | 10 kΩ or higher |
Be sure not to damage or deform the terminal being inspected.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the FC junction cable.
OK
NG
Click hereEngine / Hybrid System>FC CONTROL>CONVERTER ASSEMBLY>DISASSEMBLY
| Proceed to |
|---|
| NEXT |
NEXT
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD |
| *B | for RHD |
Disconnect the front compartment main wire connector from the inverter with converter assembly.
Make sure that no foreign matter has entered or contaminated the front compartment main wire connector.
| *A | for LHD |
| *B | for RHD |
Disconnect the No. 1 battery pack wire connector from the front compartment main wire.
Procedure1
| *1 | Shield Ground |
| *a | Front Compartment Main Wire
(Inverter with Converter Assembly Side) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A32)Location & Routingewd_type=routing;type=c;code=A32 |
||
| A32-1 (ACPE) - A32-2 (ACPB) | Ignition switch off | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the No. 1 battery pack wire connector.
Reconnect the front compartment main wire connector.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD |
| *B | for RHD |
Disconnect the No. 1 battery pack wire connector from the front compartment main wire.
Make sure that no foreign matter has entered or contaminated the front compartment main wire connector.
| *A | for LHD |
| *B | for RHD |
Disconnect the No. 1 battery pack wire connector from the electric heater sub-assembly.
Procedure1
| *1 | Shield Ground |
| *a | No. 1 battery pack wire
(Electric Heater Sub-assembly Side) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O4)Location & Routingewd_type=routing;type=c;code=O4 Click Connector(O4)Engine Compartment>EV Battery Pack Wire>Electric Heater Sub-Assemblyewd_type=component;type=c;code=O4;pinno=1,2 |
||
| O4-1 (VOL-) - O4-2 (VOL+) | Ignition switch off | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the No. 1 battery pack wire connector.
OK
NG