Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM
RM37H0E _58 Vehicle Interior _095300 HEATING / AIR CONDITIONING _0455055 AIR CONDITIONING SYSTEM T

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  PROBLEM SYMPTOMS TABLE  


NOTICE:
·

Before replacing the certification ECU (smart key ECU assembly), main body ECU (multiplex network body ECU) or EV control ECU, refer to Service Bulletin.



HINT:
·

Use the table below to help determine the cause of problem symptoms. If multiple suspected areas are listed, the potential causes of the symptoms are listed in order of probability in the "Suspected Area" column of the table. Check each symptom by checking the suspected areas in the order they are listed. Replace parts as necessary.

·

Inspect the fuses and relays related to this system before inspecting the suspected areas below.



VEHICLE CHECK ITEMS


HINT:
·

You can reduce the number of systems to check by using the results of the following operation check.

·

Perform the following checks based on customer feedback and the vehicle condition.

·

The customer's operation may not be consistent with the actual problem (eg: the cooling performance of the air conditioning is bad → actually, the wind volume is weak). It is important to check the problem symptoms accurately and judge correctly based on various sources of information.

·

Judgment as to whether the air conditioning panel is normal or abnormal can be judged by checking if the indicator illuminates or turns off when the switch is operated.

·

During servo motor initialization, the AUTO indicator light comes on, and then goes off when initialization has finished.

·

If the performance of the air conditioning is poor or there is a foul odor, check clogging in the clean air filter.



Common Function of Cool and Heater Function Only Air Function Only Heater Function Suspected Area
A/C Switch Operation Blower Operation Fresh/Recirculation Function Air Outlet Charging Function
○ ○ ○ ○ X ○ Refer to "COOLING FUNCTION:"
○ ○ ○ ○ ○ X Refer to "HEATER FUNCTION:"
X ○ ○ ○ X X Refer to "DISPLAY RELATED:"
○ X ○ ○ X X Refer to "BLOWER RELATED:"
○ ○ X ○ X X Refer to "INTAKE RELATED:"
○ ○ ○ X X X Refer to "AIR OUTLET RELATED:"
X X X X X X Air Conditioning amplifier or air conditioning unit assembly is defective


DISPLAY RELATED:


Symptom Suspected Area Link
Operations are never accepted by the air conditioning control assembly.

(With the exception of the switch indicator, everything is turned off.)


·

LIN communication between air conditioning amplifier assembly and air conditioning control assembly

·

Air conditioning amplifier assembly (+B and GND circuit)

·

Air conditioning control assembly


Click here
Operations are never accepted by the cooler control switch assembly (for 3 Zone).

(With the exception of the switch indicator, everything is turned off.)


·

LIN communication between air conditioning amplifier assembly and cooler control switch assembly

·

Air conditioning amplifier assembly (+B and GND circuit)

·

Cooler control switch assembly


Click here
Operations are never accepted by the air conditioning control assembly.

(LCD panel displayed.)


Air conditioning control assembly (for LHD) Click here
Air conditioning control assembly (for RHD) Click here
Operations are never accepted by the cooler control switch assembly (for 3 Zone). Cooler control switch assembly Click here
Operations are never accepted by the air conditioning control assembly only immediately after ignition switch ON (READY).

(LCD panel displayed.)

(Only AUTO indicator illuminates.)

(A/C switch indicator light does not illuminate.)


Refer to "INITIALIZATION" Click here
A/C switch indicator turns off.
·

Air conditioning amplifier assembly

·

Radio receiver assembly

·

A/C switch

·

One of the servo motors (initialization incomplete)

·

Damper and link operation (jamming)

·

Refrigerant pressure malfunction (low pressure)

·

Low ambient temperature (including thermistor assembly)


Click here


COOLING FUNCTION:


Symptom Suspected Area Link
No cooling at all.

(Air is discharged.)


·

Compressor with motor assembly

·

Refrigerant pressure malfunction

·

Quantity of refrigerant gas lack

·

Dirty cooler condenser

·

Cooling fan system malfunction

·

A/M servo motor

·

Damper and link operation (jamming)

·

No. 1 cooler thermistor (determined as cold, conflicting with actual temperature)

·

Warm air flow


Click here
·

Cooling is poor.

·

Takes time to cool down.


·

Customize setting

·

Compressor with motor assembly

·

Excessive refrigerant

·

Quantity of refrigerant gas lack

·

Dirty cooler condenser

·

Cooling fan system malfunction

·

A/M servo motor

·

Damper and link operation (jamming)

·

Automatic light control sensor

·

Warm air flow


Click here
Different temperature for left and right air outlets.

(Left and right stand-alone type)


·

Compressor with motor assembly

·

Quantity of refrigerant gas lack

·

A/M servo motor

·

Damper and link operation (jamming)

·

Automatic light control sensor


Click here


HEATER FUNCTION:


Symptom Suspected Area Link
·

No heating at all.

(Airflow volume control is normal.)


·

Air outlet temperature does not increase.

(Airflow volume control is normal.)



·

Low FC stack outlet coolant temperature

·

A/M servo motor

·

Damper and link operation (jamming)

·

Warm-up Control

·

Heater core closed waterway

·

PTC heater circuit

·

Heater radiator unit sub-assembly

·

Water with motor pump assembly

·

Electric heater circuit


Click here
Different temperature for left and right air outlets.

(Either left or right is warm.)


·

Water with motor pump assembly

·

Damper and link operation (jamming)

·

Heater core closed waterway


Click here
Heating performance is poor when it is cold. (w/ PTC Heater)
·

No. 1 semiconductor power integration ECU

·

Main body ECU (multiplex network body ECU)

·

Quick heater assembly

·

Air conditioning amplifier assembly

·

Harness or connector

·

Water with motor pump assembly

·

Three-way valve circuit

·

Electric heater circuit


Click here


BLOWER RELATED:


Symptom Suspected Area Link
Blower does not operate at all.

(No air comes out.)


·

Blower with fan motor sub-assembly (battery and ground circuit)

·

Control signal malfunction between air conditioning assembly and blower with fan motor sub-assembly

·

Blower with fan motor sub-assembly

·

Air conditioning amplifier assembly

·

Warm-up Control

·

FC stack outlet coolant temperature


Click here
Blower airflow volume cannot be changed.
·

Air conditioning amplifier assembly

·

Blower with fan motor sub-assembly

·

Harness or connector


Click here
·

Blower airflow volume is continuously weak.


·

Blower airflow volume is sometimes weak.


·

Customize setting

·

Control signal between air conditioning assembly and blower with fan motor sub-assembly

·

Air conditioning amplifier assembly

·

Blower with fan motor sub-assembly

·

Evaporator or heater core fin clogging

·

Clean air filter clogging

·

No. 1 cooler thermistor

·

Aspirator loser


Click here


INTAKE RELATED:


Symptom Suspected Area Link
·

Fresh/recirculation mode changes without permission.

·

Fresh/recirculation mode light blinks.


·

Customize setting

·

Change in fresh air temperature

·

Refrigerant pressure drop

·

Pressure sensor circuit

·

High FC stack outlet coolant temperature


Click here
·

Fresh/recirculation mode does not change.

·

Fresh/recirculation mode does not change automatically.

·

Exhaust gas odor when set to recirculation.


·

Blower servo motor

·

Damper and link operation (jamming)

·

Blower assembly

·

High FC stack outlet coolant temperature


Click here


AIR OUTLET RELATED:


Symptom Suspected Area Link
Air vent cannot be changed.

(Display changes)


·

MODE servo motors

·

Damper and link operation (jamming)

·

Air conditioning radiator assembly


Click here
Air vent cannot be changed.

(Display does not change)


Air conditioning control assembly (for LHD) Click here
Air conditioning control assembly (for RHD) Click here
Cooler control switch assembly (for 3 Zone) Click here
S-FLOW function does not control Control condition -
Air conditioning amplifier assembly Click here


DEFOGGER RELATED:


Symptom Suspected Area Link
Front glass fogs up.

(Does not cool)


·

Compressor with motor assembly

·

Quantity of refrigerant gas lack

·

Cooler expansion valve (opened too far)

·

DEF servo motor

·

Damper and link operation (jamming)


Click here


OPERATION RELATED:


Symptom Suspected Area Link
·

Only air conditioning system cannot be operated using the switches on the multi-display.

·

All systems (including air conditioning system) cannot be operated using the switches on the multi-display.

·

Only air conditioning system cannot be operated using the switches on the cooler control switch assembly (for 3 Zone).

·

All systems (including air conditioning system) cannot be operated using the switches on the cooler control switch assembly.


·

CAN communication between air conditioning amplifier assembly and integration control sub-assembly

·

Integration control sub-assembly

·

LIN communication between air conditioning amplifier assembly and cooler control switch assembly (for 3 Zone)

·

Cooler control switch assembly (for 3 Zone)

·

Air conditioning amplifier assembly


Click here


REMOTE AIR CONDITIONING SYSTEM RELATED:



Symptom Suspected Area Link
Remote air conditioning system cannot be operated using an application (air conditioning system is normal and ignition switch is can be turned to ON (READY)) Operation check (start, stop) Click here
Telematics transceiver Click here
Certification ECU (smart key ECU assembly) -
Main body ECU (multiplex network body ECU) Click here
Remote air conditioning system operates unintentionally Operation check (start, stop) Click here
Air conditioning amplifier assembly Click here
Telematics transceiver Click here
Main body ECU (multiplex network body ECU) Click here
Certification ECU (smart key ECU assembly) -
EV control ECU Click here